% DLT-LOGSTORAGE-CTRL(1)
dlt-logstorage-ctrl - Trigger DLT Daemon to start/stop using an offline logstorage device
dlt-logstorage-ctrl [-h] [-c ctype] [-p path] [-e ecu] [-p<prop>] [-t timeout] [-v]
Send a trigger to DLT Daemon to connect/disconnect a certain offline logstorage device
Display a short help text.
Specify connection type: connect = 1, disconnect = 0.
Run as daemon: prop = use proprietary handler
Mount point path.
Specify the ECU ID. Default is: ECU1.
Specify connection timeout. Default is: 10s.
Send message with serial header (Default: Without serial header)
Enable resync serial header
Activate the offline logstorage device mounted on /mnt/dltlog dlt-logstorage-ctrl -c 1 -p /mnt/dltlog
Deactivate the offline logstorage device mounted on /mnt/dltlog dlt-logstorage-ctrl -c 0 -p /mnt/dltlog
Run logstorage control application as daemon listen to udev events dlt-logstorage-ctrl -d
Non zero is returned in case of failure.
Christoph Lipka (clipka (at) jp.adit-jv (dot) com), Syed Hameed (shameed (at) jp.adit-jv (dot) com)
Copyright (C) 2015 Advanced Driver Information Technology, Bosch and DENSO. License MPL-2.0: Mozilla Public License version 2.0 http://mozilla.org/MPL/2.0/.
See Github issue: https://github.com/COVESA/dlt-daemon/issues
dlt-daemon(1)