dlt-daemon

% DLT-LOGSTORAGE-CTRL(1)

NAME

dlt-logstorage-ctrl - Trigger DLT Daemon to start/stop using an offline logstorage device

SYNOPSIS

dlt-logstorage-ctrl [-h] [-c ctype] [-p path] [-e ecu] [-p<prop>] [-t timeout] [-v]

DESCRIPTION

Send a trigger to DLT Daemon to connect/disconnect a certain offline logstorage device

OPTIONS

-h

Display a short help text.

-c

Specify connection type: connect = 1, disconnect = 0.

-d

Run as daemon: prop = use proprietary handler

-p

Mount point path.

-e

Specify the ECU ID. Default is: ECU1.

-t

Specify connection timeout. Default is: 10s.

-S

Send message with serial header (Default: Without serial header)

-R

Enable resync serial header

EXAMPLES

Activate the offline logstorage device mounted on /mnt/dltlog dlt-logstorage-ctrl -c 1 -p /mnt/dltlog

Deactivate the offline logstorage device mounted on /mnt/dltlog dlt-logstorage-ctrl -c 0 -p /mnt/dltlog

Run logstorage control application as daemon listen to udev events dlt-logstorage-ctrl -d

EXIT STATUS

Non zero is returned in case of failure.

AUTHOR

Christoph Lipka (clipka (at) jp.adit-jv (dot) com), Syed Hameed (shameed (at) jp.adit-jv (dot) com)

COPYRIGHT

Copyright (C) 2015 Advanced Driver Information Technology, Bosch and DENSO. License MPL-2.0: Mozilla Public License version 2.0 http://mozilla.org/MPL/2.0/.

BUGS

See Github issue: https://github.com/COVESA/dlt-daemon/issues

SEE ALSO

dlt-daemon(1)